User contributions
From LEAP
(Latest | Earliest) View (newer 50) (older 50) (20 | 50 | 100 | 250 | 500)
- 15:30, 25 March 2009 (hist) (diff) Main Page (→Applications)
- 15:29, 25 March 2009 (hist) (diff) Main Page (→Generic Application Areas)
- 15:28, 25 March 2009 (hist) (diff) Main Page (→Standard Applications)
- 15:28, 25 March 2009 (hist) (diff) Main Page (→Special Applications)
- 15:25, 25 March 2009 (hist) (diff) Main Page (→Applications)
- 15:25, 25 March 2009 (hist) (diff) N MS tuning & analytical column combination - Analyst (New page: There are four Analyst cycles that will be slight variations of the standard LC injection cycle. The first cycle is known as a Tuning cycle. It collect samples from the VT-54 tray and pa...)
- 15:24, 25 March 2009 (hist) (diff) Main Page (→Applications)
- 15:22, 25 March 2009 (hist) (diff) N Multiplexing LC injections (New page: This Cycle Composer application was used to increase sample throughput by taking advantage of front and/or back-cut time to load the next sample in the sequence early. It requires that t...)
- 15:20, 25 March 2009 (hist) (diff) Main Page (→CUSTOMER Applications)
- 14:02, 25 March 2009 (hist) (diff) N Analysis of Total Iodine (New page: A COMBI PAL will be used to mix samples with water, oxidizing hypochlorite and ascorbic acid. Followed by injection to HPLC After the addition of each reagent to the sample reagent matrix...)
- 14:01, 25 March 2009 (hist) (diff) Main Page (→CUSTOMER Applications)
- 14:00, 25 March 2009 (hist) (diff) N Intrinsic Viscosity testing (New page: This is a workstation application in which samples are prepped for viscosity testing. The prep involves adding reagent using a dilutor, then heating and mixing the sample. The viscosity me...)
- 13:59, 25 March 2009 (hist) (diff) Twin PAL - High Throughput injections using Cycle Composer
- 13:57, 25 March 2009 (hist) (diff) Main Page (→CUSTOMER Applications)
- 13:55, 25 March 2009 (hist) (diff) N Forced Degredation - Dual PAL under LEAP Shell (New page: Reaction mixtures are prepared and then incubated at 4 different temperatures. Over a period of time, samples are taken from each batch and injected to the HPLC to determine analyte stabil...)
- 13:54, 25 March 2009 (hist) (diff) Twin PAL - High Throughput injections using Cycle Composer
- 13:53, 25 March 2009 (hist) (diff) Sample Filtration with LEAP X-Press
- 13:52, 25 March 2009 (hist) (diff) Dual Channel Sample Cleanup
- 13:50, 25 March 2009 (hist) (diff) Main Page (→CUSTOMER Applications)
- 13:48, 25 March 2009 (hist) (diff) N Twin PAL - High Throughput injections using Cycle Composer (New page: The Twin PAL is used to increase throughput. It approximately doubles the injection rate of samples. Each PAL is controlled from its own session of Cycle Composer assigned to a different C...)
- 13:48, 25 March 2009 (hist) (diff) Main Page (→CUSTOMER Applications)
- 13:46, 25 March 2009 (hist) (diff) N Sample Filtration with LEAP X-Press (New page: '''General Description of the Application''' A fully automated sample prep system which is run unattended 24/7. Samples from a larger robotic system are presented in pairs to the PAL. The...)
- 13:46, 25 March 2009 (hist) (diff) Main Page (→CUSTOMER Applications)
- 13:44, 25 March 2009 (hist) (diff) N Dual Channel Sample Cleanup (New page: General Description of process: Samples are injected and pass through a guard column which is in-line with the analytical column. At a specified time, the guard column switches out of lin...)
- 13:44, 25 March 2009 (hist) (diff) Main Page (→CUSTOMER Applications)
- 15:33, 24 March 2009 (hist) (diff) LEAP X-Press Filtration Station
- 15:32, 24 March 2009 (hist) (diff) N LEAP X-Press Filtration Station (New page: {{LSApp |name = Whatman Mini-Uniprep Press |image = Vent Tool.jpg |type = '''SPECIAL''' |id = VentSample filtration |description = Accessory Showcase...)
- 15:30, 24 March 2009 (hist) (diff) Main Page (→Special Accessories)
- 15:29, 24 March 2009 (hist) (diff) Main Page (→Special Accessories)
- 14:00, 3 March 2009 (hist) (diff) Large Volume Dispensing (→Solvent Delivery System (SDS) Accessory)
- 13:56, 3 March 2009 (hist) (diff) Large Volume Dispensing
- 22:13, 24 February 2009 (hist) (diff) Large Volume Dispensing
- 22:09, 24 February 2009 (hist) (diff) N Image:SDS photo.png (top)
- 22:07, 24 February 2009 (hist) (diff) N Image:VSW II SDS.JPG (top)
- 21:49, 24 February 2009 (hist) (diff) Large Volume Dispensing
- 21:49, 24 February 2009 (hist) (diff) Image:DISP TOOL Dilutor.png (uploaded a new version of "Image:DISP TOOL Dilutor.png") (top)
- 21:47, 24 February 2009 (hist) (diff) N Image:DISP TOOL Dilutor.png
- 21:45, 24 February 2009 (hist) (diff) N Image:DISP TOOL Dilutor.jpg (top)
- 21:44, 24 February 2009 (hist) (diff) Large Volume Dispensing
- 21:28, 24 February 2009 (hist) (diff) N Image:Pump with selector valve.png (top)
- 21:26, 24 February 2009 (hist) (diff) Large Volume Dispensing
- 21:26, 24 February 2009 (hist) (diff) N Image:Vpump.png (top)
- 21:25, 24 February 2009 (hist) (diff) Large Volume Dispensing
- 21:36, 23 February 2009 (hist) (diff) Sample Filtration
- 18:36, 20 February 2009 (hist) (diff) Main Page
- 18:27, 20 February 2009 (hist) (diff) Main Page
- 18:24, 20 February 2009 (hist) (diff) Main Page (→CUSTOMER Applications)
- 18:23, 20 February 2009 (hist) (diff) Main Page (→CUSTOMER Applications)
- 18:22, 20 February 2009 (hist) (diff) N H1099 - Online Sample Cleanup using columns switching and TrioVS (New page: A setup of four valves (1 injection valve and 1 TrioVS 3-valve system) is used to accomplish solid phase sample extraction by one (1) pre-column followed by chromatography on two (2) analy...) (top)
- 18:22, 20 February 2009 (hist) (diff) N H1101 - Dilute and incubate sample before injecting to LC system (New page: The main goal is a “hands-off instrument” that executes a method that can dilute, mix and heat a sample before an injection. Customer places 50ul of chilled sample (2-8 degrees Celsiu...)
(Latest | Earliest) View (newer 50) (older 50) (20 | 50 | 100 | 250 | 500)