Summary of LC Multi Valve Applications
From LEAP
(Difference between revisions)
Line 64: | Line 64: | ||
| style="border:1px solid blue;"|* Saving of Front and Back Cut<br>* Provides "Look Ahead"<br> * Provides staggering of injections | | style="border:1px solid blue;"|* Saving of Front and Back Cut<br>* Provides "Look Ahead"<br> * Provides staggering of injections | ||
| style="border:1px solid blue;"|* Requires matching sample lists in Cycle Composer and Analyst<br>* Columns may perform slightly differently on alternating samples | | style="border:1px solid blue;"|* Requires matching sample lists in Cycle Composer and Analyst<br>* Columns may perform slightly differently on alternating samples | ||
+ | | style="border:1px solid blue;"|No | ||
+ | |} | ||
+ | <br> | ||
+ | {| cellpadding="6" style="border:1px solid darkgray;" | ||
+ | |- align=left | ||
+ | !width="20"|Code | ||
+ | !width="195"|Application | ||
+ | !width="85"|Control SW | ||
+ | !width="140"|Key Hardware | ||
+ | !width="205"|Key Benefits | ||
+ | !width="235"|Restrictions | ||
+ | !width="15"|GLP | ||
+ | |- align=left | ||
+ | | style="border:1px solid blue;"|'''M-004''' | ||
+ | | style="border:1px solid blue;"|'''Analyst with "Look Ahead" with LEAP Shell'''<br><br>Control of the Sample List is through LEAP Shell | ||
+ | | style="border:1px solid blue;"|LEAP Shell | ||
+ | | style="border:1px solid blue;"|* Standard PAL <br>* Pumps are supported within Analyst | ||
+ | | style="border:1px solid blue;"|* "look Ahead" <br> * Can import custom columns<br> * Freedom to create and use custom Cycles | ||
+ | | style="border:1px solid blue;"|* Does not support 21CFR11 compliance<br>* Requires pumps to be integrated with LEAP Shell | ||
| style="border:1px solid blue;"|No | | style="border:1px solid blue;"|No | ||
|} | |} |
Revision as of 20:56, 11 May 2009
LC Multiple Valve Applications | |
Application Type | |
STANDARD AND SPECIAL | |
Application ID | |
Description | |
Multiple Valve Applications for LC |
Code | Application | Control SW | Key Hardware | Key Benefits | Restrictions | GLP |
---|---|---|---|---|---|---|
M-001 [1] | Dual Channel Serial Injection Provides shorter cycle times by regenerating columns during next analytical run | Analyst with ICC-CE | * 6 port injection valve * 10 port Valve * Gradient Pump * Regeneration pump | * Saving of regeneration time(Back Cut) * Increase throughput at little cost * Control is all within Analyst * Compliance is not affected | * Can not do "Look Ahead" * Injections are not staggered * Peaks of interest must come of early * Columns may perform slightly differently on alternating samples | Yes |
Code | Application | Control SW | Key Hardware | Key Benefits | Restrictions | GLP |
---|---|---|---|---|---|---|
M-002 [2] | Dual Channel Serial Injection with Front Cut Provides shorter cycle times by regenerating columns during next analytical run and diverts the solvent front to waste | Analyst with ICC-CE | * Trio VS * Gradient Pump * Regeneration pump | * Saving of regeneration time(Back Cut) * Increase throughput at little cost * Control is all within Analyst * Compliance is not affected * Avoids contaminating MS inlet with early eluting compounds and solvent | * Can not do "Look Ahead" * Injections are not staggered * Peaks of interest must come of early * Columns may perform slightly differently on alternating samples | Yes |
Code | Application | Control SW | Key Hardware | Key Benefits | Restrictions | GLP |
---|---|---|---|---|---|---|
M-003 [3] | Dual Channel Parallel Injection Provides shorter cycle times by limiting the acquisition time to just the peaks of interest and regenerating columns during acquisition | Cycle Composer outside of Analyst | * DoubleStack valve * 6 port injection valve * FWS in front of 6 port valve * Gradient Pump * Regeneration pump | * Saving of Front and Back Cut * Provides "Look Ahead" * Provides staggering of injections | * Requires matching sample lists in Cycle Composer and Analyst * Columns may perform slightly differently on alternating samples | No |
Code | Application | Control SW | Key Hardware | Key Benefits | Restrictions | GLP |
---|---|---|---|---|---|---|
M-004 | Analyst with "Look Ahead" with LEAP Shell Control of the Sample List is through LEAP Shell | LEAP Shell | * Standard PAL * Pumps are supported within Analyst | * "look Ahead" * Can import custom columns * Freedom to create and use custom Cycles | * Does not support 21CFR11 compliance * Requires pumps to be integrated with LEAP Shell | No |
Code | Application | Control SW | Key Hardware | Key Benefits | Restrictions | GLP |
---|---|---|---|---|---|---|
M-005 [4] | Dual Channel Parallel Injection Provides minimum cycle times by limiting the acquisition time to just the peaks of interest and regenerating columns during acquisition | LEAP Shell | * DoubleStack valve * 6 port injection valve * FWS in front of 6 port valve * Gradient Pump * Regeneration pump | * Integration with Analyst Software * Single Sample List * Provides staggering of injections * Multiplexes 2 separate LC systems into on MS | * Does not support 21CFR11 compliance * Requires pumps to be integrated with LEAP Shell | No |
Code | Application | Control SW | Key Hardware | Key Benefits | Restrictions | GLP |
---|---|---|---|---|---|---|
M-006 [5] | Inline Sample Concentration SPE Column regenerated during analytical extraction | Analyst with ICC-CE | * TrioVS | * Automated concentration and elution of sample on SPE column prior to separation on analytical column | * No "Look Ahead" * Can not prep samples ahead of analytical run | No |
Code | Application | Control SW | Key Hardware | Key Benefits | Restrictions | GLP |
---|---|---|---|---|---|---|
M-007 [6] | Inline Sample Filtration SPE Column regenerated during analytical extraction | Analyst with ICC-CE | * TrioVS | * Automated filtration of sample on cleanup column prior to separation on analytical column | * No "Look Ahead" * Can not prep samples ahead of analytical run | No |
Code | Application | Control SW | Key Hardware | Key Benefits | Restrictions | GLP |
---|---|---|---|---|---|---|
M-008 [7] | Dual Channel In-line Sample Concentration SPE Column regenerated during analytical extraction | Cycle Composer outside of Analyst | * TrioVS | * Dual Stream * High throughput sample cleanup "Look Ahead" | * Requires two matching sample lists | No |
Code | Application | Control SW | Key Hardware | Key Benefits | Restrictions | GLP |
---|---|---|---|---|---|---|
M-009 [8] | Dual Channel in-line Sample Filtration SPE Column regenerated during analytical extraction | Cycle Composer outside of Analyst | * TrioVS | * Dual Stream * High throughput sample cleanup * "Look Ahead" | * Requires two matching sample lists | No |
Code | Application | Control SW | Key Hardware | Key Benefits | Restrictions | GLP |
---|---|---|---|---|---|---|
M-010 [9] | Dual Channel in-line Sample Concentration SPE Column regenerated during analytical extraction | LEAP Shell | * TrioVS | * High throughput sample cleanup "Look Ahead" | No |
Code | Application | Control SW | Key Hardware | Key Benefits | Restrictions | GLP |
---|---|---|---|---|---|---|
M-011 [10] | Dual Channel in-line Sample Filtration SPE Column regenerated during analytical extraction | LEAP Shell | * TrioVS | * High throughput sample cleanup "Look Ahead" | No |
Code | Application | Control SW | Key Hardware | Key Benefits | Restrictions | GLP |
---|---|---|---|---|---|---|
M-014 [11] | Selectable HPLC (max 2 Streams) | Analyst Standard Cycles | * Two Injection Valves * MS Stream Selector | * Different Analyst Methods inject into different LC Valves * Uses Standard Analyst cycles | * Requires Analyst control of the stream selector valve * Max of 2 streams can be supported | Yes |
Code | Application | Control SW | Key Hardware | Key Benefits | Restrictions | GLP |
---|---|---|---|---|---|---|
M-015 [12] | Selectable HPLC (max 4 Streams) | Analyst with ICC-CE | * Multiple Injection Valves (serial control) * PAL 10 port Valve for Stream Selector | * Different Analyst Methods inject into different LC Valves * Stream selection to MS | * PAL controls the stream selector valve * Requires Custom Cycle | Yes |
Code | Application | Control SW | Key Hardware | Key Benefits | Restrictions | GLP |
---|---|---|---|---|---|---|
M-016 [13] | Column Selection Method selects which HPLC column is in-line before injection | Analyst with ICC-CE | * CTC Column Selector * Up to 5 columns | * Automated switching between analytical columns within run | * Requires Custom Cycles | Yes |
For other cost/time saving measures consider:
- LEAP offers multiple choices of Valve Self Wash Stations to aid in cleaning the valve [14]
- LEAP Shell Software and application for custom injections and scheduling [15]
Contact LEAP
For additional information about this technique please contact LEAP Technologies for detailed information