Valve Active Self Washing

From LEAP

(Difference between revisions)
Jump to: navigation, search
(Contact LEAP)
Current revision (16:46, 11 January 2010) (view source)
(Requirements/Limitations)
 
(12 intermediate revisions not shown.)
Line 6: Line 6:
   |description = Accessory Showcase
   |description = Accessory Showcase
}}
}}
-
 
+
{{logo}}
=== Main Features ===
=== Main Features ===
-
The Active Washstation consists of two self priming PTFE micro pumps mounted next
+
The Active Washstation consists of two self priming PTFE micro pumps mounted next to the valve drive, a special needle guide assembly and a tubing set including check valve. The IN ports of the pumps are connected to the wash solvent bottles. The OUT ports are connected to the waste port of the injection valve. After sample loading and valve switch the pumps are activated. Cleaning solvent flows through the valve groove,
-
to the valve drive, a special needle guide assembly and a tubing set
+
the inside of the needle seal and is aspirated with the injection syringe. After the selected syringe cleaning time the injection syringe needle is lowered and the remaining sample between valve waste port and
-
including check valve. The IN ports of the pumps are connected to
+
check valve is flushed. As with the regular CTC Fast Washstation two different solvents can be used. (e.g. organic and aqueous). The Active Washstation setup enables entire sample flow path cleaning in backflush direction and rinses valve engravings, needle seal and syringe at the same time. It can be ordered optionally together with new instruments or as upgrade to existing [http://leapwiki.com/mediawiki/index.php?title=Category:HTS HTS] PAL / [http://leapwiki.com/mediawiki/index.php?title=Category:HTC HTC] PAL’s.
-
the wash solvent bottles. The OUT ports are connected to the waste
+
-
port of the injection valve. After sample loading and valve switch the
+
-
pumps are activated. Cleaning solvent flows through the valve groove,
+
-
the inside of the needle seal and is aspirated with the injection syringe.
+
-
After the selected syringe cleaning time the injection syringe needle is
+
-
lowered and the remaining sample between valve waste port and
+
-
check valve is flushed. As with the regular CTC Fast Washstation two
+
-
different solvents can be used. (e.g. organic and aqueous).
+
-
The Active Washstation setup enables entire sample flow path
+
-
cleaning in backflush direction and rinses valve engravings, needle seal
+
-
and syringe at the same time. It can be ordered optionally together
+
-
with new instruments or as upgrade to existing HTS PAL / HTC PAL’s.
+
=== Performance Specifications ===
=== Performance Specifications ===
Line 36: Line 24:
=== Requirements/Limitations ===
=== Requirements/Limitations ===
-
*      The PAL Active Washstation can be used with HTS PAL or HTC PAL instruments and one injection valve types VICI DCxWK conical, VICI Cheminert and Rheodyne PD series.
+
*      The PAL Active Washstation can be used with [http://leapwiki.com/mediawiki/index.php?title=Category:HTS HTS] PAL or [http://leapwiki.com/mediawiki/index.php?title=Category:HTC HTC]PAL instruments and one injection valve types VICI DCxWK conical, VICI Cheminert and Rheodyne PD series.
-
 
+
-
*      The PAL Active Wash station option can be operated with PAL firmware 2.2.4. It can be controlled either standalone or by Cycle Composer software 1.5 or higher including some of it's corresponding 3rd party instrument drivers.
+
-
== Other Reference material ==
+
*      The PAL Active Wash station option can be operated with [http://www.leapwiki.com/mediawiki/index.php?title=Category:Firmware PAL firmware 2.2.4]. It can be controlled either standalone or by [http://www.leapwiki.com/mediawiki/index.php?title=Category:Cycle_Composer Cycle Composer] software 1.5 or higher including some of it's corresponding 3rd party instrument drivers.
-
*[[:Image:VSW vs Active Wash Powerpoint.pps  | Comparison of VSW and Active Wash]]
+
=== Other Reference material ===
-
*[[:Image:ActiveWash-X-Type_000.pdf  | Active Wash Brochure]]
+
[[image:Download Icon.png|40px]] [[:Media:ActiveWash-X-Type_000.pdf  | Active Wash Brochure]]
-
== Contact LEAP ==
+
=== Accessories for the PAL ===
 +
[[image:Accessories_Icon.png|40px]] [http://www.leapwiki.com/mediawiki/index.php?title=Category:Accessories Other Accessories for PAL Robots]
-
For additional information about this technique please contact LEAP Technologies for detailed information
+
----
 +
{{logo}}
-
* [http://www.leaptec.com/contact-us.php Contact the LEAP office]
+
LEAP strives to find total solutions for analytical lab automation by automating analytical processes for small and large molecules in extracted liquids, solids, and recently in human, animal and plant tissues. We provide the precise robotics and efficient sample prep required by modern measurement techniques such as MALDITOF mass spectroscopy. Our newest specialty customization of CTC Analytics’ PAL features small workstations that can perform complex liquid handling tasks including HPLC-Purification, SPE, filtration, weighing, heating and stirring. They can be configured as stand alone units or integrated for “just in time” sample prep for LC-MS or GC-MS analysis. <br>
 +
LEAP provides automated workstation instrumentation solutions based on the LEAP CTC PAL X, Y, Z syringe only autosampler robot from LEAP Technologies. This extremely flexible, precise, and adaptable liquid handling robotic platform is available in a variety of lengths and options depending on the requirements of your sample preparation and injections for your UHPLC, LC or GC chromatography.LEAP offers full support and service for the PAL platform in addition to being able to write custom macros, cycles, and scheduling to your applications. Please contact LEAP Technologies on how we can help you get maximized throughput with flexible pipetting automation solutions.
 +
=== Contact LEAP ===
 +
{{contact|topic=LEAP and the PAL Platform}}
 +
[[Category:Accessories]]
[[Category:Valve Washing]]
[[Category:Valve Washing]]
-
[[Category:LC Inject]]
 

Current revision

Valve Active Self Washing
Application Type
  Washing LC Valve
Application ID
  Valve Active Self Washing
Description
  Accessory Showcase
 ↳ leaptec.com  ↳ leapwiki.com

Contents

Main Features

The Active Washstation consists of two self priming PTFE micro pumps mounted next to the valve drive, a special needle guide assembly and a tubing set including check valve. The IN ports of the pumps are connected to the wash solvent bottles. The OUT ports are connected to the waste port of the injection valve. After sample loading and valve switch the pumps are activated. Cleaning solvent flows through the valve groove, the inside of the needle seal and is aspirated with the injection syringe. After the selected syringe cleaning time the injection syringe needle is lowered and the remaining sample between valve waste port and check valve is flushed. As with the regular CTC Fast Washstation two different solvents can be used. (e.g. organic and aqueous). The Active Washstation setup enables entire sample flow path cleaning in backflush direction and rinses valve engravings, needle seal and syringe at the same time. It can be ordered optionally together with new instruments or as upgrade to existing HTS PAL / HTC PAL’s.

Performance Specifications

  • Pumps: 2pcs. Solenoid diaphragm pump, self priming
  • Wetted parts Pumps: PTFE and Perfluor
  • Flow Rate Range: fixed to ~50μl/sec.
  • In- Outlet pressure: max. 5psi
  • Lifetime: 20 million actuations
  • Transfer tubing kit: 2pcs. PTFE tubes 1/8 " including connection fittings
  • Solvent reservoir: 1000ml borosilicate glass including 10μm PEEK solvent filter
  • Wetted parts: All liquids compatible with borosilicate glass, PTFE, Kel-F, FEP

Requirements/Limitations

  • The PAL Active Washstation can be used with HTS PAL or HTCPAL instruments and one injection valve types VICI DCxWK conical, VICI Cheminert and Rheodyne PD series.
  • The PAL Active Wash station option can be operated with PAL firmware 2.2.4. It can be controlled either standalone or by Cycle Composer software 1.5 or higher including some of it's corresponding 3rd party instrument drivers.

Other Reference material

Active Wash Brochure

Accessories for the PAL

Other Accessories for PAL Robots


 ↳ leaptec.com  ↳ leapwiki.com

LEAP strives to find total solutions for analytical lab automation by automating analytical processes for small and large molecules in extracted liquids, solids, and recently in human, animal and plant tissues. We provide the precise robotics and efficient sample prep required by modern measurement techniques such as MALDITOF mass spectroscopy. Our newest specialty customization of CTC Analytics’ PAL features small workstations that can perform complex liquid handling tasks including HPLC-Purification, SPE, filtration, weighing, heating and stirring. They can be configured as stand alone units or integrated for “just in time” sample prep for LC-MS or GC-MS analysis.
LEAP provides automated workstation instrumentation solutions based on the LEAP CTC PAL X, Y, Z syringe only autosampler robot from LEAP Technologies. This extremely flexible, precise, and adaptable liquid handling robotic platform is available in a variety of lengths and options depending on the requirements of your sample preparation and injections for your UHPLC, LC or GC chromatography.LEAP offers full support and service for the PAL platform in addition to being able to write custom macros, cycles, and scheduling to your applications. Please contact LEAP Technologies on how we can help you get maximized throughput with flexible pipetting automation solutions.

Contact LEAP

Contact LEAP

For additional information about LEAP and the PAL Platform, please contact LEAP Technologies.

Personal tools