Pooling of vial contents for QC testing

From LEAP

(Difference between revisions)
Jump to: navigation, search
(New page: Long rail HTX PAL mounts 8 standard holders. The system is designed to pierce the vial septa, go to the bottom of the vial and wait while the in-house vacuum removes the contents. An in-ho...)
Line 2: Line 2:
The time that the instrument can stay in the aspirate position can be adjusted by the user to ensure complete recovery of the vial contents. It is expected that each vial contains 0.85ml of sample and a minimum of 0.7ml needs to be extracted. Total capacity of 400 vials. Each of the custom trays have been drilled so that the vials are held at a 15 degree angle, allowing for maximum recovery from the vial. If more than 400 vials are needed for pooling, the customer will re-fill the tray holders with new racks at a prescribed time interval. The system can be reconfigured to handle other vials sizes.
The time that the instrument can stay in the aspirate position can be adjusted by the user to ensure complete recovery of the vial contents. It is expected that each vial contains 0.85ml of sample and a minimum of 0.7ml needs to be extracted. Total capacity of 400 vials. Each of the custom trays have been drilled so that the vials are held at a 15 degree angle, allowing for maximum recovery from the vial. If more than 400 vials are needed for pooling, the customer will re-fill the tray holders with new racks at a prescribed time interval. The system can be reconfigured to handle other vials sizes.
 +
 +
 +
[[Image:Pooling_of_vials_PAL.png]]
'''Project Ref: H1115'''
'''Project Ref: H1115'''

Revision as of 20:45, 26 March 2009

Long rail HTX PAL mounts 8 standard holders. The system is designed to pierce the vial septa, go to the bottom of the vial and wait while the in-house vacuum removes the contents. An in-house vacuum flask is used to pool all of the samples.

The time that the instrument can stay in the aspirate position can be adjusted by the user to ensure complete recovery of the vial contents. It is expected that each vial contains 0.85ml of sample and a minimum of 0.7ml needs to be extracted. Total capacity of 400 vials. Each of the custom trays have been drilled so that the vials are held at a 15 degree angle, allowing for maximum recovery from the vial. If more than 400 vials are needed for pooling, the customer will re-fill the tray holders with new racks at a prescribed time interval. The system can be reconfigured to handle other vials sizes.


Image:Pooling_of_vials_PAL.png


Project Ref: H1115