Pooling of vial contents for QC testing
From LEAP
Line 11: | Line 11: | ||
=== For other cost/time saving measures consider:=== | === For other cost/time saving measures consider:=== | ||
- | + | [[image: System Icon.png|40px]] Summary of LC Multi Valve Applications [http://www.leapwiki.com/mediawiki/index.php?title=Summary_of_LC_Multi_Valve_Applications]<br> | |
- | + | [[image: System Icon.png|40px]] LEAP Shell Software and application for custom injections and scheduling [http://www.leaptec.com/software/leap-shell-3.php]<br> | |
---- | ---- | ||
[[Image:LEAP Logo.png|frame|[http://www.leaptec.com leaptec.com]<br />[http://www.leapwiki.com leapwiki.com]]] | [[Image:LEAP Logo.png|frame|[http://www.leaptec.com leaptec.com]<br />[http://www.leapwiki.com leapwiki.com]]] | ||
Line 20: | Line 20: | ||
For additional information about this technique please contact LEAP Technologies for detailed information | For additional information about this technique please contact LEAP Technologies for detailed information | ||
- | [[ | + | [[image:Contact_Info.png|40px]] [http://www.leaptec.com/contact-us.php Contact the LEAP office] |
<br><br> | <br><br> | ||
[[Category:LEAP Shell]] | [[Category:LEAP Shell]] | ||
[[Category:Example Solutions]] | [[Category:Example Solutions]] |
Revision as of 14:31, 9 June 2009
Long rail HTX PAL mounts 8 standard holders. The system is designed to pierce the vial septa, go to the bottom of the vial and wait while the in-house vacuum evacuates the contents to a flask which pools contents from all of sample vials for later testing. This application was used to batch-test vials filled with injection grade water. The task was previously performed manually.
The time that the instrument can stay in the aspirate position can be adjusted by the user to ensure complete recovery of the vial contents. In this case each vial contains 0.85ml of sample and a minimum of 0.7ml needs to be extracted. Total capacity of 400 vials. Custom trays have been drilled so that the vials are held at a 15 degree angle, allowing for maximum recovery from each vial. If more than 400 vials are needed for pooling, the customer will re-fill the tray holders with new racks at a prescribed time interval. The system can be reconfigured to handle other vials sizes.
Project Ref: H1115
For other cost/time saving measures consider:
Summary of LC Multi Valve Applications [1]
LEAP Shell Software and application for custom injections and scheduling [2]