Sandbox
From LEAP
(Difference between revisions)
Line 20: | Line 20: | ||
{| cellpadding="6" style="border:1px solid darkgray;" | {| cellpadding="6" style="border:1px solid darkgray;" | ||
- | |||
- | |||
- | |||
- | |||
- | |||
|- align=left | |- align=left | ||
- | | style="border:1px solid blue;"| | + | !width="100"|Code |
- | + | !width="200"|Application | |
- | | style="border:1px solid | + | !width="120"|Control SW |
- | + | !width="200"|Key Hardware | |
- | | style="border:1px solid | + | !width="100"|Key Benefits |
- | + | !width="100"|Restrictions | |
- | | style="border:1px solid | + | !width="100"|GLP |
- | + | |- align=left | |
- | | style="border:1px solid | + | | style="border:1px solid blue;"|M-001 |
- | + | | style="border:1px solid blue;"|Column switching with parallel regeneration <br>Provides shorter cycle times by regenerating columns during next analytical run | |
- | + | | style="border:1px solid blue;"|Analyst with ICC-CE | |
- | + | | style="border:1px solid blue;"|6 port injection valve<BR>10 port Valve <br>Gradient Pump and Regeneration pump | |
+ | | style="border:1px solid blue;"|Saving of regeneration time(Back Cut)<br> Increase throughput at little cost<br> Control is all within Analyst<br> Compliance is not affected | ||
+ | | style="border:1px solid blue;"|Can not do "Look Ahead"<br> Injections are not staggered<br> Peaks of interest must come of early<br>Columns may perform slightly differently on alternating samples | ||
+ | | style="border:1px solid blue;"|Yes | ||
|} | |} | ||
Revision as of 20:51, 28 April 2009
Testing of Wiki page location | |
Application Type | |
WIKI TEST | |
Application ID | |
ABC | |
Description | |
Wiki Testing Page for LEAP |
Quick Overview | ||||||
Code | Application | Control SW | Key Hardware | Key Benefits | Restrictions | GLP |
---|---|---|---|---|---|---|
M-001 | Column switching with parallel regeneration Provides shorter cycle times by regenerating columns during next analytical run | Analyst with ICC-CE | PAL 6 port injection valve 10 port Valve Gradient Pump and Regeneration pump | Saving of regeneration time(Back Cut) Increase throughput at little cost Control is all within Analyst Compliance is not affected | Can not do "Look Ahead" Injections are not staggered Peaks of interest must come of early Columns may perform slightly differently on alternating samples | Yes |
Code | Application | Control SW | Key Hardware | Key Benefits | Restrictions | GLP |
---|---|---|---|---|---|---|
M-001 | Column switching with parallel regeneration Provides shorter cycle times by regenerating columns during next analytical run | Analyst with ICC-CE | 6 port injection valve 10 port Valve Gradient Pump and Regeneration pump | Saving of regeneration time(Back Cut) Increase throughput at little cost Control is all within Analyst Compliance is not affected | Can not do "Look Ahead" Injections are not staggered Peaks of interest must come of early Columns may perform slightly differently on alternating samples | Yes |
Contact LEAP
For additional information about this technique please contact LEAP Technologies for detailed information