Sandbox
From LEAP
(Difference between revisions)
Line 66: | Line 66: | ||
|} | |} | ||
- | + | <br> | |
+ | == For other cost/time saving measures consider:=== | ||
+ | * LEAP offers multiple choices of Valve Self Wash Stations to aid in cleaning the valve [http://www.leapwiki.com/mediawiki/index.php?title=Valve_Washing] | ||
+ | * Dual Channel Serial Injection (M-001) using Analyst and ICC-CE [http://www.leapwiki.com/mediawiki/index.php?title=M-001_Dual_Channel_Serial_Injection_-_Analyst_with_ICC-CE] | ||
+ | * Dual Channel Serial Injection with Front Cut (M-002) using Analyst and ICC-CE [http://www.leapwiki.com/mediawiki/index.php?title=M-002_Dual_Channel_Serial_Injection_with_front_cut_-_Analyst_with_ICC-CE] | ||
+ | * Dual Channel Parallel Injection (M-003) using Cycle Composer Software and Analyst [http://www.leapwiki.com/mediawiki/index.php?title=M-003_Dual_Channel_Parallel_Injection_-_Cycle_Composer] | ||
+ | * “Look Ahead”, sample prep before injection (M-004) using LEAP Shell Software [http://www.leaptec.com/software/leap-shell-3.php] | ||
+ | * Dual Channel Parallel Injection (M-005) using LEAP Shell software [http://www.leapwiki.com/mediawiki/index.php?title=M-005_Dual_Channel_Parallel_Injection_-_LEAP_Shell_%22(M-Fab)%22] | ||
+ | * LEAP Shell Software and application for custom injections and scheduling [http://www.leaptec.com/software/leap-shell-3.php] | ||
---- | ---- |
Revision as of 23:19, 28 April 2009
Testing of Wiki page location | |
Application Type | |
WIKI TEST | |
Application ID | |
ABC | |
Description | |
Wiki Testing Page for LEAP |
Code | Application | Control SW | Key Hardware | Key Benefits | Restrictions | GLP |
---|---|---|---|---|---|---|
M-001 | Dual Channel Serial Injection Provides shorter cycle times by regenerating columns during next analytical run | Analyst with ICC-CE | * 6 port injection valve * 10 port Valve * Gradient Pump * Regeneration pump | * Saving of regeneration time(Back Cut) * Increase throughput at little cost * Control is all within Analyst * Compliance is not affected | * Can not do "Look Ahead" * Injections are not staggered * Peaks of interest must come of early * Columns may perform slightly differently on alternating samples | Yes |
Code | Application | Control SW | Key Hardware | Key Benefits | Restrictions | GLP |
---|---|---|---|---|---|---|
M-002 | Dual Channel Serial Injection with Front Cut Provides shorter cycle times by regenerating columns during next analytical run and diverts the solvent front to waste | Analyst with ICC-CE | * Trio VS * Gradient Pump * Regeneration pump | * Saving of regeneration time(Back Cut) * Increase throughput at little cost * Control is all within Analyst * Compliance is not affected * Avoids contaminating MS inlet with early eluting compounds and solvent | * Can not do "Look Ahead" * Injections are not staggered * Peaks of interest must come of early * Columns may perform slightly differently on alternating samples | Yes |
Code | Application | Control SW | Key Hardware | Key Benefits | Restrictions | GLP |
---|---|---|---|---|---|---|
M-003 | Dual Channel Parallel Injection Provides shorter cycle times by limiting the acquisition time to just the peaks of interest and regenerating columns during acquisition | Cycle Composer outside of Analyst | * Trio VS *6 port injection valve *FWS in front of 6 port valve * Gradient Pump * Regeneration pump | * Saving of Front and Back Cut * Provides "Look Ahead" *Provides staggering of injections | * Requires matching sample lists in Cycle Composer and Analyst * Columns may perform slightly differently on alternating samples | No |
For other cost/time saving measures consider:=
- LEAP offers multiple choices of Valve Self Wash Stations to aid in cleaning the valve [1]
- Dual Channel Serial Injection (M-001) using Analyst and ICC-CE [2]
- Dual Channel Serial Injection with Front Cut (M-002) using Analyst and ICC-CE [3]
- Dual Channel Parallel Injection (M-003) using Cycle Composer Software and Analyst [4]
- “Look Ahead”, sample prep before injection (M-004) using LEAP Shell Software [5]
- Dual Channel Parallel Injection (M-005) using LEAP Shell software [6]
- LEAP Shell Software and application for custom injections and scheduling [7]
Contact LEAP
For additional information about this technique please contact LEAP Technologies for detailed information