{{LSApp
 
-
  |name        = XChange
 
-
  |image      = XChange on 7890.png
 
-
  |type        = Applications
 
-
  |id          = Syringe exchange
 
-
  |description = XCHANGE® Option for automated syringe exchange
 
-
}}
 
-
{{logo}}
 
-
=== XCHANGE® Option for automated syringe exchange ===
 
-
 
-
XCHANGE® is a coupling system easily integrated onto the PAL-xt platforms giving increased flexibility.<br>
 
-
<br>
 
-
'''Automated syringe exchange enables new application possibilities with enhanced flexibility'''<br>
 
-
Main features are: <br>
 
-
• Injection of small and large volumes in one sample sequence<br>
 
-
• Syringe is exchanged, aligned and locked automatically<br>
 
-
• Syringes are available for LC or GC<br>
 
-
• Adding of internal standards without cross contamination<br>
 
-
• Preventative exchange of syringe when using harmful media<br>
 
-
• Choice of 9 different syringe volumes<br>
 
-
• Serial dilution <br>
 
-
• MEPS option for in-syringe SPE <br>
 
-
• Liquid-Liquid extraction in 2ml and 10ml vials
 
-
• Fast wash station or standard wash station
 
-
• Automatic exchange of syringes with wear during large sample batches
 
-
<br><br><br><br>
 
-
'''Automated syringe exchange enables new application possibilities with enhanced flexibility''' <br>
 
-
The XCHANGE® coupling system secures and locks the syringe in place. This is achieved by a mating mechanical piece that captures the syringe and a magnet that automatically aligns – eliminating the need for springs, screws, or alignment gauges. Once engaged the syringe is locked into position requiring zero holding force.
 
-
<br>
 
-
XCHANGE ® syringes (10µl, 25ul, 100µl, 250ul, 500ul, 1ml, 2.5ml and 5ml)<br>
 
-
<br>
 
-
The new XCHANGE® Option which is fully implemented on the PAL-xt platforms.<br>
 
-
Automated syringe exchange enables new application possibilities with enhanced flexibility.<br>
 
-
<br>
 
-
The XCHANGE® coupling system secures and locks the syringe in place. This is achieved by a mating mechanical piece that captures the syringe and a magnet that automatically aligns – eliminating the need for springs, screws, or alignment gauges. Once engaged the syringe is locked into position requiring zero holding force.<br>
 
-
<br>
 
-
''Known limitations of XCHANGE® on the PAL-xt''<br>
 
-
1. XCHANGE® is only available for PAL-xt instruments <br>
 
-
2. Requires PAL Firmware 4.2.x<br>
 
-
3. Automatic Syringe recognition of PAL-xt must be turned on<br>
 
-
4. There is only space for Wash Stations, GC inlet or Valves, CTC Agi behind the Park Station. No Tray Holder or Stack can be placed behind the XCHANGE Park Station <br>
 
-
5. Max Penetration Depth = 40mm <br>
 
-
6. XCHANGE is currently only available for the GC-xt, Combi-xt, HTS-xt instruments (80cm) <br>
 
-
 
-
=== Download of XCHANGE Flyer ===
 
-
 
-
[[image:Download Icon.png|40px]]  [[:Media:EXCHANGE_POSTER_2011.pdf‎| LEAP XCHANGE Information Document]]<br>
 
-
‎‎
 
-
[[Image:XCHANGE_Flyer.png|900px|center|XCHANGE PAL by LEAP Technologies]] ‎
 
-
<br><br>
 
-
 
-
 
-
{{contact|topic=LEAP and the PAL Platform}}
 
-
 
-
 
-
===Consumables by SGE ===
 
-
 
-
http://www.sge.com/products/syringes/xchange-syringes2
 
-
 
-
 
-
=== Keywords ===
 
-
SGE, CTC, XCHANGE® coupling system secures and locks the syringe in place, Pittcon 2011, LabAutomation 2011,XCHANGE ® syringes 10µl, 25µl, 50µl,100µl, 250µl,500µl,1000µl, 2500µl, 5000µl, 1ml, 2.5ml and 5ml,requires PAL Firmware 4.2.x,PAL-xt platforms, COMBI-xt, HTS-xt
 
-