- | {{LSApp
| |
- | |name = XChange
| |
- | |image = XChange on 7890.png
| |
- | |type = Applications
| |
- | |id = Syringe exchange
| |
- | |description = XCHANGE® Option for automated syringe exchange
| |
- | }}
| |
| | | |
- | {{logo}}
| |
- | === XCHANGE® Option for automated syringe exchange ===
| |
- | <br/><br/>
| |
- | [[image:As Seen.PNG |100px|left|As Seen at LEAP]]
| |
- | [[image:ASMS_2010.png |300px|left|As seen at ASMS 2011]]
| |
- | <br><br><br><br><br><br><br><br><br><br><br>
| |
- | XCHANGE® is a coupling system easily integrated onto the PAL-xt platforms giving increased flexibility.<br>
| |
- | <br>
| |
- | '''Automated syringe exchange enables new application possibilities with enhanced flexibility'''<br>
| |
- | Main features are: <br>
| |
- | • Injection of small and large volumes in one sample sequence<br>
| |
- | • Syringe is exchanged, aligned and locked automatically<br>
| |
- | • Syringes are available for LC or GC<br>
| |
- | • Adding of internal standards without cross contamination<br>
| |
- | • Preventative exchange of syringe when using harmful media<br>
| |
- | • Choice of 9 different syringe volumes<br>
| |
- | • Serial dilution <br>
| |
- | • MEPS option for in-syringe SPE <br>
| |
- | • Liquid-Liquid extraction in 2ml and 10ml vials<br>
| |
- | • Fast wash station or standard wash station<br>
| |
- | • Automatic exchange of syringes with wear during large sample batches<br>
| |
- | <br>
| |
- | '''Automated syringe exchange enables new application possibilities with enhanced flexibility''' <br>
| |
- | The XCHANGE® coupling system secures and locks the syringe in place. This is achieved by a mating mechanical piece that captures the syringe and a magnet that automatically aligns – eliminating the need for springs, screws, or alignment gauges. Once engaged the syringe is locked into position requiring zero holding force.
| |
- | <br><br>
| |
- | XCHANGE ® syringes (10µl, 25ul, 100µl, 250ul, 500ul, 1ml, 2.5ml and 5ml)<br>
| |
- | XCHANGE® analytical syringes can be easily and quickly changed. This allows the user to choose the best syringe for the volume being measured. It also allows the user to dedicate individual syringe to specific liquids or methods, reducing the possibility of cross-contamination. Only a few XCHANGE syringes are required to dispense liquid volumes from 0.2 μL to 500 μL.
| |
- | <br>
| |
- | The new XCHANGE® Option which is fully implemented on the PAL-xt platforms.<br>
| |
- | Automated syringe exchange enables new application possibilities with enhanced flexibility.<br>
| |
- | <br>
| |
- | The XCHANGE® coupling system secures and locks the syringe in place. This is achieved by a mating mechanical piece that captures the syringe and a magnet that automatically aligns – eliminating the need for springs, screws, or alignment gauges. Once engaged the syringe is locked into position requiring zero holding force.<br>
| |
- | <br>
| |
- | ''Known limitations of XCHANGE® on the PAL-xt''<br>
| |
- | 1. XCHANGE® is only available for PAL-xt instruments <br>
| |
- | 2. Requires PAL Firmware 4.2.x<br>
| |
- | 3. Automatic Syringe recognition of PAL-xt must be turned on<br>
| |
- | 4. There is only space for Wash Stations, GC inlet or Valves, CTC Agi behind the Park Station. No Tray Holder or Stack can be placed behind the XCHANGE Park Station <br>
| |
- | 5. Max Penetration Depth = 40mm <br>
| |
- | 6. XCHANGE is currently only available for the GC-xt, Combi-xt, HTS-xt instruments (80cm) <br>
| |
- |
| |
- | === Download of XCHANGE Flyer ===
| |
- |
| |
- | [[image:Download Icon.png|40px]] [[:Media:EXCHANGE_POSTER_2011.pdf| LEAP XCHANGE Information Document]]<br>
| |
- |
| |
- | [[Image:Cross Reference XCHANGE.jpg|600px|center|XCHANGE Syringe Reference Guide]]
| |
- | <br><br>
| |
- |
| |
- | [[Image:XCHANGE_Flyer.png|900px|center|XCHANGE PAL by LEAP Technologies]]
| |
- | <br><br>
| |
- |
| |
- |
| |
- |
| |
- | {{contact|topic=LEAP and the PAL Platform}}
| |
- |
| |
- | ===Consumables by SGE ===
| |
- |
| |
- | http://www.sge.com/products/syringes/xchange-syringes2
| |
- |
| |
- |
| |
- | === Keywords ===
| |
- | SGE, CTC, XCHANGE® coupling system secures and locks the syringe in place, Pittcon 2011, LabAutomation 2011,XCHANGE ® syringes 10µl, 25µl, 50µl,100µl, 250µl,500µl,1000µl, 2500µl, 5000µl, 1ml, 2.5ml and 5ml,requires PAL Firmware 4.2.x,PAL-xt platforms, COMBI-xt, HTS-xt, EXCHANGE PAL, ASMS 2011, Where to buy,
| |
- | [[Category:Accessories]]
| |
- | [[Category:Application_Solutions]]
| |