NMR Sample Prep

From LEAP

(Difference between revisions)
Jump to: navigation, search
(Contact LEAP)
Current revision (17:20, 27 December 2011) (view source)
(Overview)
 
(23 intermediate revisions not shown.)
Line 6: Line 6:
   |description = NMR Sample Prep  
   |description = NMR Sample Prep  
}}
}}
-
 
+
{{logo}}
=== Overview ===
=== Overview ===
-
This Twin PAL application involves the preparation of liquid samples and the transfer of them to NMR tubes. The Sample preparation step consists of adding a selected reagent then incubating the sample vial in a heated agitator for a specified length of time. Once the incubation is completed, the sample vial is returned to the sample tray and a consistent volume of the reacted sample is transferred to sealed NMR tubes. It is applicable to any customer who is doing sample prep and the loading of the NMR tubes. This type of sample prep is a necessary part of the NMR process. The objectives are to have every sample treated the same, maximize throughput, and have a consistent sample volume in the NMR tube.  
+
There are several formats available for the preparation of samples and ultimate transfer to NMR tubes.  LEAP has configurations and applications that handle flow probes, 1-mm, 3-mm and 5-mm NMR tubes commonly used by the research community.  Powered by LEAP Shell these user-defined applications are typically unique to each laboratory and often require 3rd party accessory integration.  There are Twin PAL and single PAL configurations available.  A brief document outlining these options is for viewing in the below INFORMATION section.
 +
 
 +
This [http://www.leapwiki.com/mediawiki/index.php?title=TwinPAL Twin PAL]application involves the preparation of liquid samples and the transfer of them to NMR tubes. The Sample preparation step consists of adding a selected [http://leapwiki.com/mediawiki/index.php?title=Category:Reagent_Reservoirs reagent] then incubating the sample vial in a [http://www.leapwiki.com/mediawiki/index.php?title=Agitation_of_Samples heated agitator] for a specified length of time. Once the incubation is completed, the sample vial is returned to the sample tray and a consistent volume of the reacted sample is transferred to sealed NMR tubes. It is applicable to any customer who is doing sample prep and the loading of the NMR tubes. This type of sample prep is a necessary part of the NMR process. The objectives are to have every sample treated the same, maximize throughput, and have a consistent sample volume in the NMR tube.
=== Significant Markets  ===
=== Significant Markets  ===
Line 14: Line 16:
'''What is the sample prep?'''<br/>
'''What is the sample prep?'''<br/>
-
The sample prep procedure is quite simple with the exception of the sample needing to end up in NMR tubes and maximizing throughput. Six Inkwell Reservoirs containing the reagents are available to both PAL’s. The user chooses which reagent they want to add and then the samples are loaded into a standard 6 position agitator for heating and shaking. Since the PAL can not easily move NMR tubes, all of the sample prep was done in 10ml vials with ferrous caps and then transferred to the capped NMR tubes at the end of the process. Despite its simplicity, this process requires the manual preparation of many vials at measured times. It can be a very tedious operation which requires a technician to be in the lab doing a very repetitive process.  It was important that any automation solution allow for the use of caps &septa and maximize throughput to keep up with the existing NMR’s.  
+
The sample prep procedure is quite simple with the exception of the sample needing to end up in NMR tubes and maximizing throughput. Six Inkwell [http://leapwiki.com/mediawiki/index.php?title=Category:Reagent_Reservoirs Reservoirs] containing the reagents are available to both [http://www.leapwiki.com/mediawiki/index.php?title=TwinPAL PAL's]. The user chooses which reagent they want to add and then the samples are loaded into a standard 6 position [http://www.leapwiki.com/mediawiki/index.php?title=Agitation_of_Samples heated agitator] for heating and shaking. Since the PAL can not easily move NMR tubes, all of the sample prep was done in 10ml vials with ferrous caps and then transferred to the capped NMR tubes at the end of the process. Despite its simplicity, this process requires the manual preparation of many vials at measured times. It can be a very tedious operation which requires a technician to be in the lab doing a very repetitive process.  It was important that any automation solution allow for the use of caps &septa and maximize throughput to keep up with the existing NMR’s.  
'''LEAPS Approach'''<br/>
'''LEAPS Approach'''<br/>
-
The Challenges for LEAP
 
The Twin PAL in combination with the LEAP Shell makes a very effective and flexible workstation. We were able to design and provide a solution which met the following challenges from the customer: <br/>
The Twin PAL in combination with the LEAP Shell makes a very effective and flexible workstation. We were able to design and provide a solution which met the following challenges from the customer: <br/>
1. Throughput. By using a Twin PAL we are able to take advantage of having both PALs preparing samples by sharing all of the reagents, a sample tray and NMR tube rack. <br/>
1. Throughput. By using a Twin PAL we are able to take advantage of having both PALs preparing samples by sharing all of the reagents, a sample tray and NMR tube rack. <br/>
Line 25: Line 26:
4. Provide the flexibility. LEAP Shell easily allowed the changing of the sample batch size and which reagent was to be used by the operator.<br/>
4. Provide the flexibility. LEAP Shell easily allowed the changing of the sample batch size and which reagent was to be used by the operator.<br/>
 +
[[Image:NMR2.png|600px|thumb|center|LEAP CTC Robotic NMR Sample Prep Station ]]
'''Photos'''<br/>
'''Photos'''<br/>
 +
[[image:Photo_Icon.png|40px]]
<gallery>
<gallery>
   Image:NMR1.png | LEAP NMR Prep System
   Image:NMR1.png | LEAP NMR Prep System
   Image:NMR2.png | LEAP NMR Prep System
   Image:NMR2.png | LEAP NMR Prep System
</gallery>
</gallery>
 +
=== Videos of PAL ===
 +
<br>
 +
[[Image:Movie Icon.png|40px]]
 +
[http://www.youtube.com/user/LEAPTechnologies#g/u LEAP's PAL Application Videos on YouTube]
 +
<br>
 +
----
 +
=== Information on NMR Configurations and Systems Provided by LEAP ===
 +
<br>
 +
[[image: Info icon.png|40px]]
 +
[[:Image:NMR Prep Stations offered by LEAP.pdf‎ | Overview of NMR Systems and Configurations Provided by LEAP]]<br>
 +
<br>
 +
----
 +
{{logo}}
 +
LEAP provides automated workstation instrumentation solutions based on the LEAP CTC PAL X, Y, Z syringe only autosampler robot from LEAP Technologies. This extremely flexible, precise, and adaptable liquid handling robotic platform is available in a variety of lengths and options depending on the requirements of your sample preparation and injections for your UHPLC, LC or GC chromatography.LEAP offers full support and service for the PAL platform in addition to being able to write custom macros, cycles, and scheduling to your applications. We're proud that LEAP is known as a productivity improver for laboratories, and we have big plans to even make government labs in agencies such as FDA, USDA, EPA, FBI, Armed Forces, Homeland Security and others function more efficiently. Robotic sample prep equipment works well in government labs and challenges lab technicians to keep feeding those more samples. Analytical equipment such as chromatographs and mass spectrometers are expensive devices and also expensive to maintain. The least an owner can do is to keep them running and analyze samples around the clock. LEAP has most of its lab automation robots under GSA contract and is eager to service and maintain everything it sells to keep your expensive lab equipment running around the clock. Please contact LEAP Technologies on how we can help you get maximized throughput with flexible pipetting automation solutions.
=== Contact LEAP ===
=== Contact LEAP ===
-
 
+
{{contact|topic=LEAP and the PAL Platform}}
-
* [http://www.leaptec.com/contact-us.php Contact the LEAP office]
+
[[Category:LEAP Shell]]
-
 
+
[[Category:Application_Solutions]]
-
Keywords: “NMR”, sample prep, timed-sampling, Heating, Shaking,
+

Current revision

NMR Sample Prep
Application Type
  Sample Prep
Application ID
  NMR1001
Description
  NMR Sample Prep
 ↳ leaptec.com  ↳ leapwiki.com

Contents

Overview

There are several formats available for the preparation of samples and ultimate transfer to NMR tubes. LEAP has configurations and applications that handle flow probes, 1-mm, 3-mm and 5-mm NMR tubes commonly used by the research community. Powered by LEAP Shell these user-defined applications are typically unique to each laboratory and often require 3rd party accessory integration. There are Twin PAL and single PAL configurations available. A brief document outlining these options is for viewing in the below INFORMATION section.

This Twin PALapplication involves the preparation of liquid samples and the transfer of them to NMR tubes. The Sample preparation step consists of adding a selected reagent then incubating the sample vial in a heated agitator for a specified length of time. Once the incubation is completed, the sample vial is returned to the sample tray and a consistent volume of the reacted sample is transferred to sealed NMR tubes. It is applicable to any customer who is doing sample prep and the loading of the NMR tubes. This type of sample prep is a necessary part of the NMR process. The objectives are to have every sample treated the same, maximize throughput, and have a consistent sample volume in the NMR tube.

Significant Markets

This application is ideal for those labs who wish to perform NMR sample prep needing incubation, agitation, and the loading of NMR tubes. Elements of this application could be applied to labs requiring any type of sample prep and maximizing throughput.

What is the sample prep?
The sample prep procedure is quite simple with the exception of the sample needing to end up in NMR tubes and maximizing throughput. Six Inkwell Reservoirs containing the reagents are available to both PAL's. The user chooses which reagent they want to add and then the samples are loaded into a standard 6 position heated agitator for heating and shaking. Since the PAL can not easily move NMR tubes, all of the sample prep was done in 10ml vials with ferrous caps and then transferred to the capped NMR tubes at the end of the process. Despite its simplicity, this process requires the manual preparation of many vials at measured times. It can be a very tedious operation which requires a technician to be in the lab doing a very repetitive process. It was important that any automation solution allow for the use of caps &septa and maximize throughput to keep up with the existing NMR’s.


LEAPS Approach
The Twin PAL in combination with the LEAP Shell makes a very effective and flexible workstation. We were able to design and provide a solution which met the following challenges from the customer:
1. Throughput. By using a Twin PAL we are able to take advantage of having both PALs preparing samples by sharing all of the reagents, a sample tray and NMR tube rack.
2. Throughput. Shaking and incubation of a large number of sample vials was accomplished by using two 6 position agitators. LEAP shell provided for maximizing the number of vials in the agitators.
3. Filling a capped NMR tube. This was achieved using a specially designed 32 Position NMR tube holder.
4. Provide the flexibility. LEAP Shell easily allowed the changing of the sample batch size and which reagent was to be used by the operator.

LEAP CTC Robotic NMR Sample Prep Station
LEAP CTC Robotic NMR Sample Prep Station

Photos

Videos of PAL


LEAP's PAL Application Videos on YouTube


Information on NMR Configurations and Systems Provided by LEAP


Overview of NMR Systems and Configurations Provided by LEAP


 ↳ leaptec.com  ↳ leapwiki.com

LEAP provides automated workstation instrumentation solutions based on the LEAP CTC PAL X, Y, Z syringe only autosampler robot from LEAP Technologies. This extremely flexible, precise, and adaptable liquid handling robotic platform is available in a variety of lengths and options depending on the requirements of your sample preparation and injections for your UHPLC, LC or GC chromatography.LEAP offers full support and service for the PAL platform in addition to being able to write custom macros, cycles, and scheduling to your applications. We're proud that LEAP is known as a productivity improver for laboratories, and we have big plans to even make government labs in agencies such as FDA, USDA, EPA, FBI, Armed Forces, Homeland Security and others function more efficiently. Robotic sample prep equipment works well in government labs and challenges lab technicians to keep feeding those more samples. Analytical equipment such as chromatographs and mass spectrometers are expensive devices and also expensive to maintain. The least an owner can do is to keep them running and analyze samples around the clock. LEAP has most of its lab automation robots under GSA contract and is eager to service and maintain everything it sells to keep your expensive lab equipment running around the clock. Please contact LEAP Technologies on how we can help you get maximized throughput with flexible pipetting automation solutions.

Contact LEAP

Contact LEAP

For additional information about LEAP and the PAL Platform, please contact LEAP Technologies.

Personal tools