NMR Sample Prep
From LEAP
Line 27: | Line 27: | ||
'''Photos'''<br/> | '''Photos'''<br/> | ||
+ | [[image:Photo_Icon.png|40px]] | ||
<gallery> | <gallery> | ||
Image:NMR1.png | LEAP NMR Prep System | Image:NMR1.png | LEAP NMR Prep System | ||
Line 32: | Line 33: | ||
</gallery> | </gallery> | ||
- | + | ---- | |
- | [[Image:LEAP Logo.png|frame|www.leaptec.com<br>www.leapwiki.com]] | + | [[Image:LEAP Logo.png|frame|[http://www.leaptec.com leaptec.com]<br />[http://www.leapwiki.com leapwiki.com]]] |
=== Contact LEAP === | === Contact LEAP === | ||
Line 39: | Line 40: | ||
For additional information about this technique please contact LEAP Technologies for detailed information | For additional information about this technique please contact LEAP Technologies for detailed information | ||
- | + | [[image:Contact_Info.png|40px]] [http://www.leaptec.com/contact-us.php Contact the LEAP office] | |
<br><br> | <br><br> | ||
[[Category:LEAP Shell]] | [[Category:LEAP Shell]] |
Revision as of 11:40, 9 June 2009
NMR Sample Prep | |
Application Type | |
Sample Prep | |
Application ID | |
NMR1001 | |
Description | |
NMR Sample Prep |
Overview
This Twin PAL application involves the preparation of liquid samples and the transfer of them to NMR tubes. The Sample preparation step consists of adding a selected reagent then incubating the sample vial in a heated agitator for a specified length of time. Once the incubation is completed, the sample vial is returned to the sample tray and a consistent volume of the reacted sample is transferred to sealed NMR tubes. It is applicable to any customer who is doing sample prep and the loading of the NMR tubes. This type of sample prep is a necessary part of the NMR process. The objectives are to have every sample treated the same, maximize throughput, and have a consistent sample volume in the NMR tube.
Significant Markets
This application is ideal for those labs who wish to perform NMR sample prep needing incubation, agitation, and the loading of NMR tubes. Elements of this application could be applied to labs requiring any type of sample prep and maximizing throughput.
What is the sample prep?
The sample prep procedure is quite simple with the exception of the sample needing to end up in NMR tubes and maximizing throughput. Six Inkwell Reservoirs containing the reagents are available to both PAL’s. The user chooses which reagent they want to add and then the samples are loaded into a standard 6 position agitator for heating and shaking. Since the PAL can not easily move NMR tubes, all of the sample prep was done in 10ml vials with ferrous caps and then transferred to the capped NMR tubes at the end of the process. Despite its simplicity, this process requires the manual preparation of many vials at measured times. It can be a very tedious operation which requires a technician to be in the lab doing a very repetitive process. It was important that any automation solution allow for the use of caps &septa and maximize throughput to keep up with the existing NMR’s.
LEAPS Approach
The Challenges for LEAP
The Twin PAL in combination with the LEAP Shell makes a very effective and flexible workstation. We were able to design and provide a solution which met the following challenges from the customer:
1. Throughput. By using a Twin PAL we are able to take advantage of having both PALs preparing samples by sharing all of the reagents, a sample tray and NMR tube rack.
2. Throughput. Shaking and incubation of a large number of sample vials was accomplished by using two 6 position agitators. LEAP shell provided for maximizing the number of vials in the agitators.
3. Filling a capped NMR tube. This was achieved using a specially designed 32 Position NMR tube holder.
4. Provide the flexibility. LEAP Shell easily allowed the changing of the sample batch size and which reagent was to be used by the operator.