Revision as of 02:04, 9 June 2009
Biofuels | |
Application Type | |
Sample Inject | |
Application ID | |
Biodiesel EN14110 | |
Description | |
Determination of Methanol content by Headspace |
Contents |
Overview
EN14110 describes the required method for methanol determination in biodiesel. A high methanol content can raise vapor pressure and increase flammability in biodiesel.
Significant Markets
- Biodiesel Manufactures
- Biodiesel Blenders
- Biodiesel Distributors
- Biofuels CROs
- Fleet Managers
EN Method 14110
EN 14110: Fat and oil derivatives – Fatty Acid Methyl Esters (FAME) - Determination of methanol content
Biodiesel can consist of different fatty acid methyl esters, depending on the oils used during production. For the determination of methanol in such a complex matrix, gas chromatography in combination with headspace injection is the recommended method. This enables separation of low-boiling methanol from the high-boiling fatty acid methyl esters already during the sample preparation step.
The biodiesel samples are heated in a gas-tight 20 mL vial. Methanol is a low-boiling point compound and is enriched in the gas-phase while the high-boiling point compounds remain in the liquid phase. After a specific time, equilibrium is reached and a constant volume can be sampled from the gas-phase (headspace) of the vial and injected into the GC system.
GC Run time is approximately 10 minutes
Photos
Software Control
Currently the COMBI PAL and runs on via the hand held due to the desire for look ahead funcationality.
The incubation time is 45 minutes and the GC runtime is approximately 10 minutes
Can also be run under Cycle Composer or Agilent CTC control software without look ahead functionality.
Screenshots
Useful links
A good general reference site by Agilent [1]
UCONN.com A good general reference site on Biodiesel without buying the ASTM Methods [2]
www.biodiesel.org A good general reference site on Biodiesel [3]
Biodiesel Plant Listing [4]
Biodiesel Conference 2009 [5]
Contact LEAP
For additional information about this technique please contact LEAP Technologies for detailed information